Measure your sound.
Choose your microphone and source, calibrate if needed, record a sweep, then explore your response.
Your measurement in four steps.
- Microphone & source: choose the input and the device playing sound.
- Calibrate level: play white noise, enter a matching Z / unweighted meter reading and capture it, or skip.
- Set up sweep: select duration, band and level. Record here, or play the exported sweep from your external source.
- Response: see the raw response, apply a time gate, then smooth or scale the graph and export.
For measured crossover data, open a recording or response and select stereo transfer or import response text. The full guide explains the microphone and loopback setup →.
Phone Quick measure
A side tool for quick, relative checks using your phone microphone and PC playback. Run a sweep and compare before & after.
Before measuring: set up your speaker & microphone
- Place the speaker. Use stable support with clear space around it. For driver design, keep the intended baffle or cabinet; for a whole-speaker check, leave the crossover in place.
- Fix the microphone position. Choose the reference axis, record distance and height, and follow the microphone’s calibration orientation. Keep a phone steady with its mic opening clear. Keep position and gain fixed between repeat captures.
- Connect and check. Playback source → amplifier → loudspeaker. The microphone connects separately to the PC through USB or an interface; Phone Quick measure uses a paired phone. Start at low amplifier volume, select the correct input and check for clipping. Choose a sweep band suitable for the driver.
- Measure, then gate. Use relative dB if you have no external level reference. Capture twice without moving anything. Inspect the direct arrival and first reflection before choosing the gate; a short window cannot resolve deep bass.
Watch the 36-second setup video → · Read the setup guide → · UMC202HD + ECM8000 setup →
Instructional videosSix simple walkthroughs · 25–40 seconds each
Set up your speaker & microphone
Silent, captioned guides to physical setup and the website’s controls. Example values, pairing states and synthetic responses are for demonstration. Press Play, or read the steps below.
Read the video steps
Dedicated microphone measurement
Connect a USB measurement microphone or a microphone through an audio interface. Select your source, calibrate if needed, record a sweep and review the response using the four steps below.
Choose a way to start.
This workflow keeps recordings on this device. Quick measure transfers audio directly to your paired PC. No sign-up needed.
Set up your input.
Follow the checklist to begin.
Choose your dedicated microphone or audio interface input. Play the sweep through this PC’s browser output, or use an external player / DAW.
Device names appear after permission. If output selection is unsupported, choose the output in your system sound settings.
Connect your selected output to the loudspeaker amplifier. Browser playback does not automatically pass through a DAW; select the interface output or use the external/DAW option.
- 1Place your microphone
Face your phone or microphone toward the loudspeaker and keep its position steady.
- 2Play a little sound
Use a separate player or your normal music source. Start at low volume.
- 3Start and allow access
Tap Start microphone below. Your browser will ask for microphone permission.
A phone gives a relative spectrum. Accurate SPL or driver response needs a calibrated measurement setup.
Choose a microphone & see input settings
After access, available microphones appear here. Stop capture before changing input, then start again.
Recording channel
A spectrum shows the frequencies in your recording. It does not isolate the driver's response.
Your stereo file must contain a microphone measurement and a simultaneous line-level loopback reference, recorded on the same clock. Select the microphone channel above; the other channel is the reference.
Keep microphone position, timing and level consistent across drivers. Never connect a speaker-level amplifier output directly to an audio-interface input.
Show the recording setup →Have a REW .mdat session? Export the selected measurement as text in REW first. Show the short REW import guide →
- 1Choose your playback device
Select the loudspeaker's audio output in your phone or computer sound settings.
- 2Start with low volume
Use a frequency range suitable for your driver. Keep a tweeter's protective crossover in place.
- 3Play or save the test sound
Play it now or download a WAV to use with another player.
5-second sweep · 20 Hz–20 kHz · −30 dBFS
Adjust frequency, duration & level
This makes a test signal. It does not record a response or calculate room decay.
Optional: match an external sound-level reading
Play the calibration noise through your loudspeaker at low volume. Hold the reference meter and microphone at the same position. Enter the meter’s unweighted / Z-weighted reading while the sound is steady, then capture three seconds. Skip calibration to work in relative dB.
The button generates band-limited white noise (500 Hz–2 kHz, −30 dBFS RMS). Keep your driver’s protection in place. This is a level reference for this microphone, gain and test; it does not certify microphone accuracy.
For an external source, play the downloaded WAV or open this page on the source device.
No external level reference yet. Relative measurements are available.
Advanced microphone frequency correction & offset
Skip this for a first look. For calibrated work, use the correct microphone response-error file and a level offset established from a known reference.
Error is subtracted within the file's frequency range. A level offset alone does not establish accurate SPL. Calibration explained →
Keep your microphone fixed on the driver axis. Choose a suitable sweep band and start with low amplifier volume. Recordings remain on this device.
The browser will play and record your sweep together.
Download this exact sweep and play it once from your external player / DAW after recording starts. Do not change its duration, band, speed or EQ. Start within three seconds of the “play now” message. Separate clocks make this an approximate response; timing is unconfirmed.
Use an existing stereo sweep recording
Microphone and electrical reference must be recorded simultaneously on the same interface clock, with silence before and after the sweep. This is a microphone/reference transfer in relative dB, not an automatic absolute SPL measurement. Set the sweep’s actual frequency band above.
Ready to record. Read the gated-measurement guide →
Your result.
Review & process your data
Smoothing and custom graph limits affect the display. Export stays unsmoothed unless selected above. Level shift is included in export. Raw data is kept in memory; phase samples are retained, not synthesized or time-aligned.
Apply a time gate / inspect the impulse
Optional: exclude room reflections
The raw response appears first. Inspect the impulse and end the gate before the first reflection to isolate the direct response.
Raw audio is retained while you adjust the gate. A short gate cannot resolve bass accurately: export excludes frequencies below twice the inverse gate duration. The taper and original recording time origin are preserved. Browser output/input latency is not a common timing reference.
Keep your measurement
Measurement details & limits
Phone and browser processing can affect measurements. Spectra are relative frequency content; transfer analysis requires a simultaneous reference. Read the scope and limitations →.
Choose a way to start.
Tool guides for your next step
Browse all speaker design tools & guides →
- Measured crossover design and optimizerImport FRD and ZMA driver measurements, build series/shunt RLC branches and optimize unlocked components. Preserve reference settings and save your project.