JBL 2240H · January 1982 preliminary
Exact 8 Ω 2240H reference from a January 1982 preliminary JBL sheet. The preliminary status is retained rather than presenting it as a final or later production specification. No 2240J or replacement-driver specifications are substituted.
Driver specifications
- Brand
- JBL
- Type
- Woofer
- Nominal size
- 460 mm / 18 inches — nominal
- Nominal impedance
- 8 Ω
- Document revision
- JBL SS2240H-1/82 — PRELIMINARY SPECIFICATIONS
- Source checked
- 2026-10-06
- Power input / program rating
- 600 W continuous program in the preliminary January 1982 sheet
- Sine-wave rating
- 300 W continuous sine-wave rating listed in the preliminary sheet; not AES
- Sensitivity
- 98 dB SPL at 1 m with 1 W input; swept signal from 100–500 Hz, on axis
- Published frequency range
- 30–2000 Hz. Usable frequency range in the preliminary sheet; not a flat-response guarantee.
- Maximum recommended crossover
- 800 Hz. Highest recommended crossover frequency; not a minimum safe crossover.
- Nominal voice-coil diameter
- 100 mm. Manufacturer metric nominal diameter; edgewound copper ribbon
- Overall frame diameter
- 464 mm
- Baffle cutout
- 427 mm. Front mounting; rear mounting has a separate opening.
- Overall depth
- 191 mm. Published overall depth, not a separately defined behind-flange dimension
- Rear-mounting cutout
- 422 mm
- Mounting bolt circle
- 441 mm
- Driver displacement
- 8.5 litres
Metric dimensions transcribed from the original preliminary drawing/table. Verify final production geometry before machining.
This original sheet specifies that positive voltage on the black input terminal moves the diaphragm forward. Confirm the actual unit and any recone before wiring.
Thiele/Small parameters
Historical T/S parameters are withheld until the exact version is corroborated in two credible sources. No values are inferred from photographs or another variant.
Technical sources & availability
Original JBL technical document at Lansing Heritage ↗
Out-of-production historical reference. Used-market stock, condition, reconing and original components require individual confirmation.
Documents remain hosted by the external archive. No original scans, manufacturer photographs, PDF files or CAD files are redistributed here. Confirm the exact original unit and drawing before machining.